Keyword Recirculating Chiller Ultra-low Temp Chillers SUNDI series TES series Products

LN (-60℃ ~ -10℃)
LN (-60℃ ~ -10℃)
LN (-60℃ ~ -10℃)
LN (-60℃ ~ -10℃)
LN (-60℃ ~ -10℃)

Refrigeration Unit LN series

  • Temperature Range-60℃ ~ -10℃
  • Circulation Pump Info6.6m³/h~50m³/h
  • Cold Storage tank200L~4000L
  • Cooling Capacity AT -40℃12kW ~ 360kW
  • Power max 380V50HZ14kW ~ 300KW
  • Place of OriginChina
  • Quality Guarantee Period12 months

Product Details

FEATURES:

The basic principle of Ultra-Low Temp. Water-Cooled Chiller is that under ultra-low temperature, the movement of molecules is slowed down until the surface of the trapped and frozen cryogenic coiled tubes is slowed down, and the vapor is easy to be arrested, set and frozen, and the capture rate is high.

LNEYA specializes in the production of single-fluid cryogenic chillers. The refrigeration temperature ranges from -150°C to -5°C, which can meet the needs of different refrigeration temperatures. Products are widely used in chemical, pharmaceutical, biochemical and other industries in the field of low temperature reaction, refrigeration speed, safety and reliability. The company developed a direct-cooled ultra-low temperature chiller, using international brand compressors Carrier, using automatic cascade refrigeration mode and mixed refrigerants, within 3 minutes can be refrigerated to minus 120°C.

PRINCIPLE:

1.Temperature ranges from -5℃ ~ -150℃, can meet different temperature
2. Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK. Bitzer, Copeland, Handbell, fusheng; Plate heat exchanger, Small volume, High efficiency
3. Top imported cold controller; Generator cooling water circuit uses intermediate heat exchanger, improve system reliability and safety.
4. DANFOSS electronic expansion valve, high precision control;
5. Adopt Siemens PLC S7-200/300, LNEYA touch screen, automatic control, temperature curve display, temperature record U disk, fault alarm;
6. Offer machine installation and system test, users only need to finish the installation of refrigerant and cooling water.

Model LN-6W LN-10W LN-20W LN-30W LN-40W LN-60W LN-120W LN-180W
Temperature Range -60°C~ -10°C
Cooling Capacity
At -40°C
12kw 20kw 40kw 60kw 80kw 120kw 240kw 360kw
  10320Kcal/h 17200Kcal/h 34400Kcal/h 51600Kcal/h 68800Kcal/h 103200Kcal/h 206400Kcal/h 309600Kcal/h
Cooling Capacity 
At -55°C
6kw 10kw 20kw 30kw 40kw 60kw 120kw 180kw
  5160Kcal/h 8600Kcal/h 17200Kcal/h 25800Kcal/h 344000Kcal/h 51600Kcal/h 103200Kcal/h 154800Kcal/h
Circulation Pump Info 6.6m³/h 9m³/h 15m³/h 25m³/h 25m³/h 25m³/h 35m³/h 50m³/h
  2.5bar max 2.5bar max 2.5bar max 2.5bar max 2.5bar max 2.5bar max 2.5bar max 2.5bar max
Inlet&outlet connection size DN-25
PN-10
DN-25
PN-10
DN-32
PN-10
DN-40
PN-10
DN-40
PN-10
DN-40
PN-10
DN-50
PN-10
DN-65
PN-10
Cooling Water at 30 degree 10m³/h 14m³/h 25m³/h 30m³/h 35m³/h 50m³/h 90m³/h 120m³/h
Cold Storage tank (optional) 200L 350L 750L 1000L 1200L 1500L 3000L 4000L
Expansion tank(standard) 100L 175L 350L 500L 600L 750L 1350L 1800L
Compressor Emerson Scroll compressor,Carlyle;Dorin Carlyle、HANBELL、Fusheng、Bitzer screw compressor
                 
Operation Panel 7-inch color touch screen display, temperature curve record
Control System SIEMENS S7 PLC&Module,Set temperature difference of refrigeration on & off
Closed Circulation System The whole system is a full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature
Circulation Pump LNEYA Mangetic Pump/German Brand Mangetic Pump
Evaporator Danfoss/KAORI plate heat exchanger
Condenser Casing type water-cooled condenser / tube-type water-cooled condenser
Intermediate heat exchanger Danfoss/KAORI plate heat exchanger
Refrigeration accessory Oil separators, drying filters, expansion valves, refrigeration solenoid valves, pressure control, mirrors, etc. all use Emerson / Danfoss and other brands
Electric AC contactors, intermediate relays, circuit breakers, thermal relays, etc. are Schneider / ABB brand
Refrigerant R404A/R23 mixture,optional: R125/R23 mixture
Secondary refrigerant No corrosive liquid, ethanol water, heat transfer oil etc.
Safety Protection High pressure protect; water supply cut-off protection; over-current protection; leakage protection; sequential and phase failure protection; High temperature protection; Sensor Failure protection; Liquid low level protection etc. multi-safety protection
Level Indicator Adopt glass liquid level indication
Piping material Expansion tank, cold storage tank and circulation pipeline are all made of SUS304
Case material Channel steel + square tube + cold rolled plate        sealing plate spray 7035
Dimension cm 100*150*185 205*145*205 205*145*175 245*145*205 300*160*225 350*160*205 500*200*225 650*200*225
Power 14kW 18kW 35kW 52kW 69kW 104kW 200kW 300kW
dB within 75dB    within 90 dB
Weight (kg) 850 1000 1450 2000 2400 3000 4200 5600
Optional Optional outside touch screen display controller (separated), the communication line distance is 10 meter
Optional Optional explosion-proof touch screen control system (ExdeIIBT4), the communication line distance is 15 meter
SUBMIT A MESSAGE TO INQUIRE ABOUT THIS PRODUCTAfter receiving your information, we will contact you as soon as possible, and your contact information will be ensured not to be disclosed
*
*
*
Submitting! Please wait…
Submitted successfully! We will contact you as soon as possible!
Failed to submit! Please try again later…
邮箱错误!
电话错误!
OBTAIN SPECIAL TEMPERATURE CONTROL SOLUTION!After receiving your information, we will contact you as soon as possible.
*
*
Submitting! Please wait…
Submitted successfully! We will contact you as soon as possible!
Failed to submit! Please try again later…
邮箱错误!
电话错误!

RECOMMENDED PRODUCTS

loading…

已经是到最后一篇内容了!

Expand more!