Keyword Recirculating Chiller Ultra-low Temp Chillers SUNDI series TES series Products

SUNDI (-45 ~ 250℃)

SUNDI (-45 ~ 250℃)

  • Temperature Range-45 ~ 250℃
  • Temperature Control Accuracy±0.5℃
  • Heating Power3.5KW ~ 200KW
  • Cooling Capacity AT 0℃3KW ~ 200KW
  • Circulating Pump Flow and Pressure35~600L/min 2~2.5BAR
  • Power Supply6.5 ~ 280KW
  • Place of OriginChina
  • Quality Guarantee Period12 months

Product Details

FEATURES:

Typical Applications Of Cooling Heating Chiller: dynamic constant temperature control of high pressure reactor cold and heat source, dynamic constant temperature control of double-layer glass reactor cold and heat source, dynamic constant temperature control of double-layer reactor cold and heat source, constant temperature of microchannel reactor Control; small thermostat control system, steaming system temperature control, material low temperature high temperature aging test, combined chemical cold source heat source constant temperature control, semiconductor equipment cooling heating, vacuum chamber cooling heating constant temperature control.

Dynamic Temperature Control System Advantages And Functions: temperature range from -120℃ to 350℃, superior performance, high precision, intelligent temperature control. Multi-function alarm system and safety function, 7-inch, 10-inch color TFT touch screen graphic display, magnetic drive pump, no shaft seal leakage problem.

Ultra-high Temperature Cooling Technology Can Directly Cool Down From 300 High Temperature. Because only the heat transfer medium in the expansion chamber is in contact with the oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the heat transfer medium. The risk of oxidizing and absorbing moisture from the air. No high-temperature heat medium evaporates at high temperature, and continuous control can be achieved with -80℃ to 190℃, -70℃ to 220℃, -88℃to 170℃, -55℃ to 250℃, and -30℃ to 300℃ without pressurization temperature. 

Model SUNDI
-535
SUNDI
-535W
SUNDI
-555
SUNDI
-555W
SUNDI
-575
SUNDI
-575W
SUNDI
-5A10
SUNDI
-5A10W
SUNDI
-5A15
SUNDI
-5A15W
SUNDI
-4A25
SUNDI
-4A25W
SUNDI
-4A38W
SUNDI
-4A60W
SUNDI
-4A95W
SUNDI
-4A130W
SUNDI
-4A200W
Temp. range -45℃~+250℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 10 programs, each program can edit 40 steps.
Communication Portocol MODBUS RTU Protocol, RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment, reactor material temp.(external temp. sensor)
Medium temp. acccuracy ±0.5℃ ±1℃
Material temp. accuracy ±1℃ ±1.5℃
Heating power kW 3.5 5.5 7.5 10 15 25 38 60 95 130 200
Cooling capacity kW at 250℃ 3.5 5.5 7.5 10 15 25 38 60 95 130 200
  100℃ 3.5 5.5 7.5 10 15 25 38 60 95 130 200
  20℃ 3.5 5.5 7.5 10 15 25 38 60 95 130 200
  0℃ 3 5 7 10 15 25 38 60 95 130 200
  -20℃ 1.5 2.9 4.2 6 11 16 26 34 50 70 120
  -40℃ 0.45 0.9 1.5 2 3.8 4.7 9 12 18 24 43
Circulation pump max
L/min bar
35 35 50 60 110 150 200 250 400 400 600
    2 2 2 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Pump LNEYA magnetic drive pump German magnetic drive pump
Compressor Emerson, Danfoss, Italy Dorin,French Tecumseh.
Expansion valve Emerson thermal expansion valve/danfoss thermal expansion valve.
Evaporator DANFOSS/KAORI Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R507C, optional: R448A
Connection size G3/4 G3/4 G3/4 G1 G1 DN32 PN10 DN40 PN10 DN50 PN10 DN50 PN10 DN65 PN10 DN65 PN10
Water-cooled type W(cooling water@20℃) 800L/H
1.5bar~4bar
1500L/H
1.5bar~4bar
1800L/H
1.5bar~4bar
2600L/H
1.5bar~4bar
3200L/H
1.5bar~4bar
7m³/H
1.5bar~4bar
12m³/H
1.5bar~4bar
17m³/H
1.5bar~4bar
24m³/H
1.5bar~4bar
32m³/H
1.5bar~4bar
42m³/H
1.5bar~4bar
Dimension(water type)cm 45
*85
130
55
*100
*175
55
*100
*175
70
*100
*175
80
*120
*185
100
*150
*185
/ / / / /
Dimension(air type)cm 45
*85
*130
45
*85
*130
45
*85
*130
55
*100
*175
55
*100
*175
80
*120
*185
100
*150
*185
205
*145
*205
205
*145
*205
245
*145
*205
300
*160
*225
Isolate size(air type) cm 45
*110
*130
55
*120
*170
55
*120
*170
70
*125
*175
80
*145
*185
105
*120
*185
100
*175
*185
205
*145
*205
205
*145
*205
245
*145
*205
300
*160
*225
Positive pressure(water type)cm 110
*95
*195
110
*95
*195
110
*95
*195
110
*95
*195
135
*145
*195
(135+60) 
*145
*225
(135+60) 
*145
*225
(185+60) 
*145
*225
(185+100) 
*145
*225
(185+100) 
*145
*225
(185+150) 
*165
*225
Weight kg 180 195 260 320 390 620 820 1100 1350 1680 2250
Power 380V 50HZ 6.5kW 9kW 11.5kW 16kW 23kW 36kW 55kW 89kW 135kW 180kW 280kW
SUBMIT A MESSAGE TO INQUIRE ABOUT THIS PRODUCTAfter receiving your information, we will contact you as soon as possible, and your contact information will be ensured not to be disclosed
*
*
Submitting! Please wait…
Submitted successfully! We will contact you as soon as possible!
Failed to submit! Please try again later…
邮箱错误!
电话错误!
OBTAIN SPECIAL TEMPERATURE CONTROL SOLUTION!After receiving your information, we will contact you as soon as possible.
*
*
Submitting! Please wait…
Submitted successfully! We will contact you as soon as possible!
Failed to submit! Please try again later…
邮箱错误!
电话错误!

RECOMMENDED PRODUCTS

loading…

已经是到最后一篇内容了!

Expand more!