Keyword Recirculating Chiller Ultra-low Temp Chillers SUNDI series TES series Products

SUNDI (-25 ~ 200℃)

SUNDI (-25 ~ 200℃)

  • Temperature Range-25 ~ 200℃
  • Temperature Control Accuracy±0.5℃
  • Heating Power2.5KW ~ 200KW
  • Cooling Capacity AT 20℃2.5KW ~ 200KW
  • Circulating Pump Flow and Pressure20~600L/min 2~2.5BAR
  • Power Supply4 ~ 260KW
  • Place of OriginChina
  • Quality Guarantee Period12 months

Product Details

FEATURES:

Typical Applications Of Cooling Heating Chiller: dynamic constant temperature control of high pressure reactor cold and heat source, dynamic constant temperature control of double-layer glass reactor cold and heat source, dynamic constant temperature control of double-layer reactor cold and heat source, constant temperature of microchannel reactor Control; small thermostat control system, steaming system temperature control, material low temperature high temperature aging test, combined chemical cold source heat source constant temperature control, semiconductor equipment cooling heating, vacuum chamber cooling heating constant temperature control.

Dynamic Temperature Control System Advantages And Functions: temperature range from -120℃ to 350℃, superior performance, high precision, intelligent temperature control. Multi-function alarm system and safety function, 7-inch, 10-inch color TFT touch screen graphic display, magnetic drive pump, no shaft seal leakage problem.

Ultra-high Temperature Cooling Technology Can Directly Cool Down From 300 High Temperature. Because only the heat transfer medium in the expansion chamber is in contact with the oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the heat transfer medium. The risk of oxidizing and absorbing moisture from the air. No high-temperature heat medium evaporates at high temperature, and continuous control can be achieved with -80℃ to 190℃, -70℃ to 220℃, -88℃to 170℃, -55℃ to 250℃, and -30℃ to 300℃ without pressurization temperature. 

Model SUNDI-
225
SUNDI-
225W
SUNDI-
235
SUNDI-
235W
SUNDI-
255
SUNDI-
255W
SUNDI-
275
SUNDI-
275W
SUNDI-
2A10
SUNDI-
2A10W
SUNDI-
2A15
SUNDI
-2A15W
SUNDI-
2A25
SUNDI-
2A25W
SUNDI-
2A38W
SUNDI-
2A60W
SUNDI-
2A95W
SUNDI-
2A130W
SUNDI-
2A200W
Temp. range -25℃~+200℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp.
difference
Set or control the temperature difference between jacket oil and raw material process
Program Editor 10 programs, each program can edit 40 steps.
Communication
Portocol
MODBUS RTU Protocol, RS485 interface
Material temp.
feedback
PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment,reactor material temp.(external temp. sensor)
Medium temp.
acccuracy
±0.5℃   ±1℃
Material temp.
accuracy
±1℃ ±1.5℃  
Heating power kW 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
Cooling
capacity
kW at
200℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
100℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
50℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
20℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
-5℃ 2 3 4.5 6.6 8 12 19 30 46 70 80 125
-20℃ 1 1.8 2.8 3.8 4.6 7 12 16 22 32 43 65
Circulation pump
max  L/min bar
20 35 35 50 50 110 150 200 250 400 400 600
2 2 2 2 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Compressor Mitsubishi Emerson copeland vortex flexible Dorin seni-closed compressor
Expansion valve Emerson thermal expansion valve/danfoss thermal expansion valve.
Evaporator DANFOSS/KAORI Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid
low level protection, high temperature protection and temperature fault protection.
Closed circulation
system
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature,
pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A,optional: R448A/R125
Connection size G1/2 G3/4 G3/4 G1 G1 G1 DN32 DN40 DN40 DN50 DN65 DN65
Water-cooled type
W(@20℃)
600L/H 800L/H 1000L/H 1200L/H 1600L/H 2200L/H 6m³/H 10m³/H 14m³/H 20m³/H 28m³/H 36m³/H
Dimension
(water type)cm
55
*68
*145
55
*68
*145
55
*68
*145
55
*100
*175
70
*100
*175
70
*100
*175
100
*150
*185
/ / / / /
Dimension
(air type)
cm
50
*85
*130
55
*100
*175
55
*68
*145
55
*100
*175
70
*100
*175
80
*120
*185
80
*120
*185
100
*95
*185
205
*145
*205
205
*145
*205
245
*145
*2250
275
*160
*225
Isolate size
(air type)
cm
45
*110
*130
45
*110
*130
55
*120
*170
55
*120
*170
70
*125
*175
80
*145
*185
105
*120
*185
100
*95
*185
205
*145
*205
205
*145
*205
205
*145
*205
275
*160
*225
Positive pressure
(water type)
cm
110
*95
*195
110
*95
*195
110
*95
*195
110
*95
*195
110
*95
*195
135
*145
*195
(135+60)
*145
*225
(135+60)
*145
*225
(185+60)
*145
*225
(185+100)
*145
*225
(185+100)
*145
*225
(185+150)
*165
*225
Weight kg 115 165 185 230 280 300 550 750 1000 1250 1580 2150
Power 380V 50HZ AC 220V 4kW 6kW 8kW 11kW 14kW 21kW 34kW 52kW 79kW 123kW 165kW 260kW
 
SUBMIT A MESSAGE TO INQUIRE ABOUT THIS PRODUCTAfter receiving your information, we will contact you as soon as possible, and your contact information will be ensured not to be disclosed
*
*
Submitting! Please wait…
Submitted successfully! We will contact you as soon as possible!
Failed to submit! Please try again later…
邮箱错误!
电话错误!
OBTAIN SPECIAL TEMPERATURE CONTROL SOLUTION!After receiving your information, we will contact you as soon as possible.
*
*
Submitting! Please wait…
Submitted successfully! We will contact you as soon as possible!
Failed to submit! Please try again later…
邮箱错误!
电话错误!

RECOMMENDED PRODUCTS

loading…

已经是到最后一篇内容了!

Expand more!