  • Temperature Range40℃ ~ 100℃
  • Flow Rate Accuracy±0.2L/min
  • Heating Power7.5kW~ 38kW
  • Cooling Capacity AT 20℃7.5kW ~ 60kW
  • Power 380V50HZ16.5kW~81kW
  • Groups Number2 Groups
  • Place of OriginChina

Product Details

FEATURES:

Applicable to the new generation of energy battery pack, which can effectively test the Chao of the battery pack, strong environmental adaptability, improve the safety and reliability of the whole vehicle, and ensure the good operation of the vehicle in a variety of complex environments.

The products are widely used for limit performance test of motor and battery pack, rapid temperature rise and fall thermal shock test, and comprehensive environmental adaptability evaluation test.

The temperature variation range is usually from – 40 to 100 degrees (which can be extended to 150 degrees). While controlling the temperature, you can also choose to control the flow or pressure; it is equipped with a strong circulating pump to ensure the transmission of high viscosity liquid; frequency conversion regulation or proportional regulation valve is used to control the flow output to achieve high-precision control, and the total range can be adjusted by 5% ~ 100%.

PRINCIPE:

The tested object is connected to a test platform adapter; The parts are cooled and heated by glycol aqueous solution; The test component needs to experience a specific temperature change curve and record the temperature change.

On test benches in the automotive industry, high-precision temperature control systems are used for material and component testing, enabling precise adjustment and rapid temperature changes. Only precise temperature management can provide reliable and repeatable results. In addition to the temperature of the medium, the temperature control system can also accurately control the flow rate and working pressure. Temperature control systems are mainly used in two ways: to simulate external environmental conditions in a climate chamber or to replace internal systems, such as the cooling circuit of an engine.

 
Model Synbol Unit KRY-475/475W/2S KRY-4A15W/2S KRY-4A25W/2S KRY-4A38W/2S KRY-4A60W/2S
Temp Range  -40℃~+100℃
Flow rate output L/min 1~20 L/min 1~20 L/min 1~20 L/min 1~40 L/min 1~40 L/min
Flow rate accuracy  L/min ±0.2 L/min
Heating power kW 7.5kW 10kW 15kW 25kW 38kW
Cooling Capacity 100℃ 10kW 15kW 25kW 38kW 60kW
200℃ 10kW 15kW 25kW 38kW 60kW
0℃ 10kW 15kW 25kW 38kW 60kW
 -35℃ 2.5kW 4kW 6.5kW 10kW 15kW
Refrigerant   R404A/R507C/R125/N40
Power 380V50HZ kW max 16.5kW 24kW max 36kW max 56kW max 81kW max
Dimension(A) cm (A) cm 70*100*175 80*120*185 100*150*185 120*180*205 145*205*225
Weight (water cooling) KG 360KG 450KG 750KG 1000KG 1700KG
Compression Emerson Valley Wheel Compressor
Expansion valve/solenoid valve Danfoss Thermal Expansion Valve / Emerson Solenoid Valve
Oil distributor Emerson
Dry filter, Pressure control Danfoss
Evaporator Danfoss/KAORI plate heat exchanger
Circulating pump German brand magnetic drive pump
Frequency converter Delta
Flow,Pressure sensor Electromagnetic flowmeter, Johnson Controls pressure sensor
Input, Display 10 inch color touch screen \ Siemens S7-1200 PLC controller
Communication Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol
Safety protection With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions
Closed circulation
system
The whole system is a fully closed system, there will be no oil mist at high temperature, low temperature does not
absorb water in the air, the system in operation will not because of high temperature pressure rise, low temperature
automatically add heat conduction medium.
refrigerant R404A/R507C/R125/N40 All four refrigerants are available
Connection size There are two groups of inlet and outlet, G3/4
Cooling water@20C 2500L/H 4000L/H 8000L/H 12000L/H 18000L/H
Condenser(W) Shenshi tube type heat exchanger
Condenser(A) Optional air-cooled type, upper air outlet, the equipment size will be increased.
Power 380V50HZ 16.5kW 24kW max 36kW max 56kW max 81kW max
Dimension cm 70*100*175 80*120*185 100*150*185 120*180*205 145*205*225
Weight(W) 360KG 450kg 750kg 1000kg 1700kg
Optional 220V 60HZ Three phase 400V 50HZ Three phase 440V 60HZ Three phase
Optional Extend to -40~+135℃
Optional The size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load,
pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp.
SUBMIT A MESSAGE TO INQUIRE ABOUT THIS PRODUCTAfter receiving your information, we will contact you as soon as possible, and your contact information will be ensured not to be disclosed
*
*
Submitting! Please wait…
Submitted successfully! We will contact you as soon as possible!
Failed to submit! Please try again later…
邮箱错误!
电话错误!
OBTAIN SPECIAL TEMPERATURE CONTROL SOLUTION!After receiving your information, we will contact you as soon as possible.
*
*
Submitting! Please wait…
Submitted successfully! We will contact you as soon as possible!
Failed to submit! Please try again later…
邮箱错误!
电话错误!

RECOMMENDED PRODUCTS

loading…

已经是到最后一篇内容了!

Expand more!